Determination of Memantine hydrochloride in rats’plasma by precolumn derivation-HPLC

SU Li,MAO Hui-ying,ZHANG Dan,CAO Jun-han,CHEN Wen-zhi
2009-01-01
Abstract:OBJECTIVE To establish a pre column derivation HPLC method for the detemination of Memantine hydrochloride ( MH) concentration in rats’plasma. METHODS The concentrations of Memantine hydrochloride in rats’plasma were measured by RP HPLC after extraction with dichloromethane and derivated with amantadine. Separation and determination were achieved on a Luna C18 column( 150 mm × 4. 6 mm,5 μm) with the mobile phase of methanol water triethylamine ( 70:30:0. 5) . The UV detection wavelength was set at 225 nm. The fluid speed was 1. 0 mL·min -1. RESULTS There was no interference found during the determination. Good linear relationship of the Memantine hydrochoride was obtained between 0. 14 to 9. 20 μg·mL -1 ( r = 0. 9950) . The mean method recovery were 112. 01% ,99. 96% ,99. 10% . Extraction recovery were 83. 46% ,80. 34% ,82. 77% . The RSD within day were 10. 24% ,8. 97% ,6. 94% . The between day RSD were 12. 10% ,8. 77% ,4. 60% ,respectively. CONCLUSION The methods are sensitive,accurate with a wide line,and suitable for the internal study of Memantine hydrochoride.
What problem does this paper attempt to address?