Improvement of the equivalent dose determination using aliquots of potassium feldspar

jiafu zhang,shenghua li,my w tso
DOI: https://doi.org/10.1016/S1350-4487(00)00132-3
IF: 1.743
2001-01-01
Radiation Measurements
Abstract:A procedure of preheat/measurement, dose/preheat/measurement and preheat/measurement is proposed, in which all the measurements for the equivalent dose determination are made on a single aliquot of K-feldspar sample with the additive-dose method. Correction for the loss of IRSL signal due to preheat/measurement cycles is made using correction factors determined both at the beginning and the end of the measurement cycle. It is suggested that the optimal preheat condition for the sample can be determined by comparing the correction factors obtained from the two stages of analysis, as a function of preheat temperature. The most appropriate preheat for our K-feldspar sample is at 235°C for 10 min.
What problem does this paper attempt to address?