Comparative Study on Clˉ Penetration in Cracked High Ductility and Low Shrinkage Material and Steel Fiber Concrete

ZHANG Jun,ZHONG Hai-tao,JU Xian-chun,WANG Guan-ming
DOI: https://doi.org/10.3969/j.issn.1007-9629.2012.02.001
2012-01-01
Abstract:The effect of cracks in steel fiber concrete(SFRC) and high ductility and low shrinkage material(LSECC) on Cl-penetration was investigated by pre-induced flexural cracks in concrete beams.The cracked beams with different crack width or tensile strains were then continuously soaked with 3%(by mass) NaCl solution or undergone drying and wetting cycles.The content(by mass) of Cl-in concrete at the locations of cracks was determined by drilling powder sample with electric hammer.The experimental results show that the influence of cracks on the Cl-penetration is very significant.The content of Cl-at the location of cracks in SFRC is 3-4 times compared to the place without cracks.The Cl-content in SFRC is increased with increase of the crack width for the specimens soaked for 30 d.At 60 d after soaked,the content of Cl-becomes almost constant irrespective of the penetration depth.Under drying and wetting conditions,the content of Cl-in SFRC greatly increases compared to those of continuously soaked.By contrast,LSECC can apparently reduce the content of Cl-,especially under drying and wetting conditions.The resistance to Cl-penetration for LSECC is obviously significant.
What problem does this paper attempt to address?