InfIuence of Ioad crack on chIoride diffusion in concrete

Chuanqing FU,Shenjie LU,Xianyu JIN,Xinzhu ZHOU
DOI: https://doi.org/10.3969/j.issn.1002-3550.2015.02.002
2015-01-01
Abstract:Cracks existed in reinforced concrete structure under loading will shorten the chloride diffusion path,which will cause steel corrosion in the concrete crack zone.In present study,8 specimens of ordinary concrete(CO)and granulated blast furnace slag mixed concrete( CS)with natural crack were prepared,and the crack in the specimen was produced by secondary loading method. The chloride diffusion test was conducted in the constant temperature and salt water immersing condition. Chloride ions distribution range and chloride concentration was determined by silver nitrate chromogenic method and scanning electron probe analysis,respectively. The test results in-dicated that specimens with natural load crack can be used to non-steady chloride transport test. Chloride concentration gradient appears in the crack surface,in which the gradient decreased with crack width increasing. Crack depth is affected by the crack width,so,the chloride diffusion depth is correspondingly affected by the crack width. Granulated blast furnace slag mixed in concrete is beneficial for chloride diffusion resistance ability and improving the concrete structure service performance. The research results can be a reference to establish a accurate chloride diffusion model.
What problem does this paper attempt to address?