Comparative study of MSCT bolus tracking and visual manual trigger in the head CTA imaging application

YU Li-xin,JIN Jian-jun,WANG Cai-yun
DOI: https://doi.org/10.3969/j.issn.1004-0412.2012.31.022
2012-01-01
Abstract:Objective To research the image quality of head CTA imaging with MSCT bolus tracking technology and visual manual trigger scanning technology contrastingly.Method 50 cases who were suspected of head arterial disease with application of Siemens SOMATOM sensation40 CT,divided into 2 groups,group A and group B.23 cases in group A used intelligent tracking technology and 27 cases in the group B used visual manual trigger technology to get the(CTA) head artery data acquisition imaging,and then collected data post-processing restructuring through the syngo V32 workstations.Results The image quality of the two groups were evaluated respectively based on the image quality assessment standards.In group A,20 cases were class A and 3 cases were class B.In group B,15 cases were class A,6 cases were class B and 6cases were class C.Conclusion Using the intelligent tracking technology and visual manual scanning technology properly to trigger the head(CTA) data collection and combine them can ensure the success of the check and get a better image.