A study of the preparation variables of tubular positive electrodes for lead/acid batteries

H.W. Yang,Y.Y. Wang,C.C. Wan
DOI: https://doi.org/10.1016/0378-7753(85)80059-8
IF: 9.2
1985-01-01
Journal of Power Sources
Abstract:The effects, during formation, of current density, charge capacity, and concentration and temperature of H2SO4 electrolyte on the capacity of tubular electrodes in lead/acid batteries have been studied. Electrode capacity was found to be maximum at a H2SO4 concentration of 1.05 sp. gr., a charge amount of 250% theoretical capacity, a current density of 0.44 A dm−2, and an electrolyte temperature of 40 °C. A study of the soaking process for tubular electrodes showed the electrode capacity to be maximum when the acid absorption was about 170 mg of H2SO4 per g of oxide. Finally, the discharge overpotential of tubular electrodes was analyzed by a galvanostatic transient method.
What problem does this paper attempt to address?