Numerical Simulation and Performance Tests on Layered-combustion in a Tangential Coal-fired Double-furnace Boiler

LIANG Shaohua,NING Xinyu,ZHANG Enxian,HUANG Lei,ZHOU Hao,CEN Kefa
DOI: https://doi.org/10.13334/j.0258-8013.pcsee.2011.26.008
2011-01-01
Abstract:The boiler would suffer severe ash deposition propensity when only Shenhua coal with low ash fusion temperature was supplied.Taking Shenhua coal with low ash fusion temperature and Pinghun coal with high ash fusion temperature as fuel in a 1 025 t/h double-furnace boiler,the numerical simulation and performance tests of layered-combustion were performed.The velocity and temperature distribution of furnace area were analysed by numerical simulation,the characteristic of combustion,emission and economy were studied by performance tests.The research results show that the increase of Shenhua coal's quantity proportion in total coal supply and the heightening of Shenhua coal's burning layer position in the boiler combustion system would make ash deposition propensity more seriously and NOx emission decrease,but boiler efficiency wasn't influenced obviously.When Shenhua coal was fired on different burning layers or the proportion in total coal supply was changed,the optimization of distribution of secondary air should be obtained by adjustment tests.
What problem does this paper attempt to address?