Low-level Radioactive Wastewater Treatment by Continuous Electrodeionization

LIU Lijun,LI Fuzhi,ZHAO Xuan,ZHAO Gang
DOI: https://doi.org/10.3321/j.issn:1000-0054.2008.06.025
2008-01-01
Abstract:The continuous electrodeionization (CEDI) technology was used in low-level radioactive wastewater treatment to minimize radioactive wastes and energy consumptions, with Cs, Co, and Sr chosen as the typical fission products of pressurized water reactor (PWR). The results show that the CEDI has better continuous and effective operation performance compared with conventional ion exchange processes, with a removal efficiency of strontium of more than 95%. The nuclide removal efficiency decreases with increasing ratio of influent to effluent. The CEDI technology exhibits nuclide removal efficiencies from high to low in the order of Cs+, Sr2+, and Co2+, which is different from the conventional ion exchange.