Removal of high level boron in aqueous solutions using continuous electrodeionization (CEDI)

Bei Jiang,Xue Zhang,Xuan Zhao,Fuzhi Li
DOI: https://doi.org/10.1016/j.seppur.2017.10.012
IF: 8.6
2018-01-01
Separation and Purification Technology
Abstract:•High level boron acid solutions were treated with a lab-scale CEDI stack.•The removal efficiency of boron increased with the increasing current.•Decreasing the dilute compartment feed flow rate promoted the removal of boron.•The optimal pH value was found to be 10.•Three main factors influencing the removal of boron was identified.