Experimental study and finite element analysis on the new type connections of a project

Nie Jianguo,Zhu Dan,Yin Xufeng
DOI: https://doi.org/10.19701/j.jzjg.2013.21.001
2013-01-01
Abstract:The traditional column-beam and concrete wall-steel beam connections have the disadvantages of complex conformation,difficult construction and so on.Considering the disadvantages of the traditional connections,combining with an engineering example,new column-beam composite joint and concrete wall-steel beam hinge joint have been designed.Experimental study on seismic performance of scale components was conducted,which showed that failure on beam ends was occurred and strong connection-weak component seismic requirements were achieved.Finite element analysis was accomplished to further grasp the force characteristics of the new joints.Moreover,influence factors on the bearing capacity of the new column-beam composite joint were studied through finite element analysis.The results indicate that the greatest impact on the bearing capacity of column-beam joints is the inner baffle,secondly the embedded T column.In condition of the same inner baffle,the depth of T column shows more obvious effect on the bearing capacity than the height of T column.