Effects of Different Electro-deposition Methods on Microstructure and Corrosion Resistance of Ni-nanoAl_2O_3 Composite Coating

SHI Shu-Yun,MA Wen-Ying,CHANG Li-Min,CHEN Dan,WANG Li-Mei
2008-01-01
Abstract:Composite coatings of Ni-nanoAl2O3 were obtained by direct current(DC),pulse current(PC) and pulse reverse current(PRC) electro deposition techniques.The effects of different coating methods on the structure of the composite coating were studied and the cross-section morphology and microstructure of the Ni-nano Al2O3 were analyzed by scanning electron microscopy(SEM),transmission electron microscopy(TEM),and XRD.Corrosion resistance of the coating to 3.5% NaCl solution was performed.The result showed that the prep method can significantly affect the coating microstructure and matrix grain size.The minimum size of the metal matrix Ni grains in the composition coating obtained by PRC deposition was approximately 24 nm,while the maximum grain size of Ni obtained by DC was about 38 nm.Polarization test indicated that the corrosion resistance of the composite coating Ni-nano Al2O3 deposited by PRC was the optimal one,while that by DC was the worst.The corrosion current and corrosion voltage were 2.8×10-7 A and-0.225 V for composite coating Ni-nanoAl2O3 deposited by PRC,and 3.16×10-6 A and-0.328 V for that deposited by the latter,respectively.
What problem does this paper attempt to address?