Comparison Between HPLC and LPLC with Ion Exchange for Assaying HbA1c

冯雪凤,贾支俊,黄群,郭万华
DOI: https://doi.org/10.3969/j.issn.1671-7171.2007.12.030
2007-01-01
Abstract:【Objective】To compare high performance liquid chromatography(HPLC) with low performance liquid chromatography(LPLC) by ion exchange for the automatic and accurate separation of hemoglobin A1c(HbA1c).【Methods】 HPLC and LPLC with ion exchange were used to assay HbA1c in 100 patients with diabetic mellitus,and the results were analyzed by correlation.The quality of HbA1c was controlled by two methods for five times respectively.【Results】The mean of HPLC and LPLC were 8.15±2.27 and 8.33±2.43 respectively.The linear equation was Y=0.96X+0.53(r=0.99,P0.01,n=100).Both methods showed homogeneous results(χ2=0.65) which were consistency.Results of qualitative control were close to the target value and CV was low.【Conclusion】 Both HPLC and LPLC for assaying HbA1c show homogeneous results.Both of them are believable measurements.
What problem does this paper attempt to address?