STUDY ON LOADING CHARACTERISTICS OF V TYPE COMPOSITE INSULATOR USED IN 330KV COMPACT

Yue Bo,HOU Lei,WANG Li-ming,Zhu Pu-xuan
DOI: https://doi.org/10.3321/j.issn:0258-8013.2005.15.017
2005-01-01
Abstract:V type composite insulator string, which has advantages of light weight, easy cleaning, high tensile strength and stable post buckling, is a key component of compact line. The main destination of this paper is to study the loading characteristics of V type composite insulator used in 330kV compact line. Firstly, the mechanical characteristics of compressed composite insulator are studied based on the large flexivity theory, and the compression amplitude is measured in the large flexivity experiment. Therefore the destruction stress of composite insulator is calculated based on large flexivity theory and the compression amplitude responding to destruction. Secondly, displacement along x and y direction, axial compression amplitude and stress with loading ratio and included angle are studied in mechanical loading experiment. In addition,the preferred included angle of V type composite insulator string is suggested so as to guide the design of compact line. Finally, the composite insulator string with 65° included angle is adopted in the design of Tian-Cheng 330kV compact line based on theoretical analysis and experiment presented in the paper.
What problem does this paper attempt to address?