Preparation of A Novel Cooh Ion Implantation Sensor and Its Application

Gao Dong-Mei,Zhao Dan-Ling,Hu Jing-Bo,Li Qi-Long
DOI: https://doi.org/10.1002/cjoc.200890006
IF: 5.56
2008-01-01
Chinese Journal of Chemistry
Abstract:A novel ion implantation sensor (DNA/COOH/ITO) based on DNA immobilization in COOH/ITO probe was manufactured for the first time. The surface morphologies of the electrodes were characterized by X-ray photoelectron spectroscopy (XPS), field-emission-scanning electron microscopy (FSEM) and electrochemical methods. In a 0:5 mol/L PBS solution, a sensitive oxidation peak of DNA on the COOH/ITO electrode was obtained by voltammetry. The electrochemical behavior of DNA was studied. And the oxidative peak potential of DNA was +0.400 V (vs. Ag/AgCl). Its peak current was proportional to the concentration of DNA over the range of 1.0 X 10(-8)-1.0 * 10(-6) mol/L with a detection limit of 5.0 X 10(-9) mol/L (about 0.5 ng/mL). This sensor was applied to the direct detection of DNA samples.
What problem does this paper attempt to address?