Preparation of a Novel NH2+Ion Implantation Modified Electrode and Its Study of the Electrochemical Behavior of Hemoglobin

DongMei Gao,Jing Bo Hu,Qi Long Li,WeiHai Fang
DOI: https://doi.org/10.1080/00032710701484392
2007-01-01
Analytical Letters
Abstract:A novel functional electrode was obtained by implanting NH2+ into ITO film (NH2/ITO) for the first time. The NH2/ITO surface showed a better affinity to gold nanoparticles than bare ITO. Gold nanoparticles were deposited on the surface of NH2/ITO electrode (Au/NH2/ITO). The Au/NH2/ITO and NH2/ITO electrodes were used to observe the electrochemical behavior of Hemoglobin (Hb) immobilized on the electrodes surfaces. The peak current value of Hb immobilized on NH2/ITO increased compared with on bare ITO while peak current value of Hb immobilized on Au/NH2/ITO increased compared with on Au/ITO. Linkage between the -NH2 implanted into the ITO film and the -COOH of Hb was thought to be the reason for the increase of active Hb coverage on NH2/ITO compared with bare ITO. Increase of active Hb coverage on Au/NH2/ITO compare with Au/ITO was attributed to the different amount of gold nanoparticles deposited. Results showed the novel NH2/ITO and Au/NH2/ITO electrodes exhibited good stability, reproducibility besides selectivity and sensitivity. The electrode process of Hb immobilized on Au/NH2/ITO was quasi-reversible with adsorption. The electrode reaction rate constant k(s) and other related constants were determined. X-ray photoelectron spectroscopy (XPS), field-emission scanning electron microscopy (FE-SEM), and impedance spectra were used to characterize the different surfaces.