Electrostatic Probe Diagnosis on the Plasma in the Discharge Chamber of an Electron Cyclotron Resonance Ion Thruster

Yang Juan,Wang Yang,Meng Zhiqiang,Li Pengfei
DOI: https://doi.org/10.13433/j.cnki.1003-8728.2013.02.024
2013-01-01
Abstract:Electron cyclotron resonance ion thruster is a type of static electric thruster,and it has the advantages of high specific impulse,electrodeless and high durability,which make the thruster competitive in the applications of deep space probe and long life satellite.The discharge chamber is the key component of electron cyclotron resonance ion thruster.Within the discharge chamber,applied magnetic field,microwave and plasma are coupled together.It is important to understand the plasma parameters for the optimization of the chamber structure and its performances.At the assumption of unmagnetized ions in the chamber and with Langmuir probe,the electron temperature and ion number density are diagnosed directly.The results show that at argon mass flow rate of 3 sccm and 8 sccm,and the output power of 10 W and 34 W,the electron temperature and ion density are diagnosed from 1 eV to 6.8 eV and 2×1016/m3 to 2.8×1017/m3 respectively.
What problem does this paper attempt to address?