Microwave Plasma Thruster Plume Diagnosis Using Microwave Interference Method

He Wusheng,Mao Genwang,Chen Maolin,Yang Juan,Wang Xikui,Long Chunwei
DOI: https://doi.org/10.13433/j.cnki.1003-8728.2010.02.019
2010-01-01
Abstract:An experiment system for Microwave Plasma Thruster (MPT) plume diagnosis with microwave interference device was built,and the electron density of MPT plume with propellant Argon was diagnosed,and the axial distribution of electron density and the influence of thruster power and propellant flowrate on electron density is determined. Experimental results show that the electron density of MPT plume is about 0. 5 × 1016 /m3 ~ 2 × 1016 /m3 and it decreases along the axial direction when the distance from thruster nozzle is more than 300mm; and that the enhancement of thruster power and propellant flowrate can increase the electron density effectively. The electron density distribution and changing trend are in good agreement with the Langmuir probe diagnosis result,which verified the feasibility of microwave interference method on MPT plume measurement.
What problem does this paper attempt to address?