Qualitative Fit Test of Medical Protective Masks :A Comparative Study

纪晋文,张震,王慧雯,初艳慧,刘潇潇,刘国涛,刘建山,孙强,张振伟,高霞
2012-01-01
Abstract:OBJECTIVE To compare the suitability of N95 particulate mass protective face mask between 3MTM9132 and 1869 type for medical use,and to promote the medical workers′ knowledge of selection method about N95 protection face mask.METHODS The suitability of N95 particulate mass protective face mask of 3MTM9132 and 1860 type was tested for medical use from 3M company by 3M FT-30 fit testing equipment.RESULTS The level of sensitivity of all the 185 objects in group A was 1,and 176 medical staff participated in the suitable fit test of 3MTM9132 type for medical use all passed at first time,and 6 participants passed the qualitative fit test after adjusting,and 3 participants gave up the test because of hypersusceptibility.13 in 637 of group B were insensitive to bitter,the rest of participants who participated in the suitable fit test of 3MTM1860 type for medical use were classified into of level 1(87.28%),level 2(7.69%) and level 3(2.98%);of 624 medical staff involved in the sensitivity test,598 participants passed the qualitative fit test,the difference in the pass rate of the suitable fit test between the participants wearing two types of protective face masks was statistically significant(χ2=7.83,P0.05).CONCLUSION The two types of medical protective mask at the same protection level have different effect on the qualitative fit test,and it is necessary for the medical staff to choose the protective masks suitable for their personal use.