Experimental Study on Structural Performance of Wood-Steel-Wood Bolted Joints

Ai-feng XI,Wei-qing LIU,Hui-feng YANG,Xiao-hong WEN
DOI: https://doi.org/10.3969/j.issn.1005-6270.2009.05.005
2009-01-01
Abstract:The bearing capacity of bolted wood-steel-wood connections loaded parallel to grain is studied in this paper.Five groups of specimen with different connection type were tested to analyse the failure modes and failure mechanism.A decreasing ductility of joints was observed at the increase of the number of bolts.The effective number of fasteners was evaluated according to Eurocode、CSA、NDS and compare with experimental results.Eurocode N.5 provide values for the bolt effectiveness quite closer to experimental results.
What problem does this paper attempt to address?