Test study for the performance of wood-cold-formed steel frame shear walls with difference detailed configurations

LIU Yan,ZHANG Chao,XU Yuanfei
DOI: https://doi.org/10.3969/j.issn.1008-1933.2013.06.019
2013-01-01
Abstract:The wood-cold-formed steel frame shear wall is a new structure system which timber is used to instead cold-formed steel as the top,bottom plates. Considering different studs spacing and different self-tapping screws spacing,four groups of wood-cold-formed steel frame shear walls were constructed and done monotonic and cyclic loading test. The damage phenomenon and shear strength as well as lateral stiffness of the specimen were analyses after the test. The results show that the spacing of the studs and self-tapping screws decrease,the shear strength and the lateral stiffness of specimen increase,the studs spacing affect the properties of shear wall greater than the self-tapping screws spacing.
What problem does this paper attempt to address?