Thermodynamic Analysis of Valve-Controled Metal Hydride Refrigeration System

Zhang Jipeng,Fu Qinsheng,Guo Xiaokun,Zhang Zaoxiao
DOI: https://doi.org/10.3969/j.issn.0253-4339.2006.03.001
2006-01-01
Abstract:A dynamic model of performance analysis for valve-controlled metal hydride heat pumps was established.Computing simulation was used to explore the operation of valve-controlled metal hydride heat pumps.The effects of intermediate temperature,specific heat at constant pressure,mass ratio of hydride to the beds,and heat transfer coefficient on the dynamic performances were obtained.The results show that higher intermediate temperature will reduce both COP and cooling capacity,and specific heat at constant pressure of hydride beds can not affect COP and cooling capacity greatly.Moreover,improving mass ratio of hydride to the beds can improve COP but reduce the cooling capacity.Further,improving heat transfer coefficient can improve COP and cooling capacity significantly.On the basis of our computing results,some measures were proposed to improve the dynamic performance of the system.
What problem does this paper attempt to address?