Preparation of Flow-through Tubular Ion-selective Electrode for the Determination of Anionic Surfactants

Wei Fu-xiang
2006-01-01
Abstract:A flow-through tubular ion-selective electrode(ISE) responsive to anionic surfactants is reported.This ISE is prepared by using carbon tube as matrix material,and trimethyl ammoniym bromide as the electroactive substance.The electrode performance has been experimentally tested.The results show that this ISE has a wide linear range of 1.6×10~(-7)-5.1×10~(-3) mol/L for determining dodecylbenzene sulfonate(DBS~-).Its Nernstian slope is 52 mV·decade~(-1) within pH range of 2.50-10.50.The detection limit is 2.0×10~(-8) mol/L,and the life time of the electrode is about 50 d.The electrode has been applied to the determination of anionic surfactants in water,the average recovery is(95%-)104%.