IGBT Open Circuit Fault Diagnosis Method for Inverter

YU Yong,JIANG Shengcheng,YANG Rongfeng,WANG Gaolin,XU Dianguo
DOI: https://doi.org/10.13334/j.0258-8013.pcsee.2011.09.002
2011-01-01
Abstract:Inverter IGBT open circuit fault diagnosis methods are comparatively studied,through comparison of the average current Park vector method,three-phase average current method and the proposed normalization based on Fourier transform method,experimental results show that the average current Park vector method and three-phase average current method can accurately diagnose IGBT open circuit fault and perform fault location,but wrong diagnosis often occurs in sudden loading or sudden load reduction conditions.The proposed normalization method solves the dynamic wrong diagnosis problem by normalizing the motor current average value according to fundamental component.Experiments based on dSPACE platform demonstrate the validity of the proposed method.
What problem does this paper attempt to address?