Numerical Simulation of Temperature Field of Melting Pools with Different Horizontal Width in the Bottom of Float Glass Furnace

刘洪源,高华,沈锦林,宋晨路,韩高荣
DOI: https://doi.org/10.3969/j.issn.1004-3950.2009.06.005
2009-01-01
Energy Engineering
Abstract:Numerical simulation of melting tank in a float glass furnace with 460 t/d was performed.The influence on production capacity and temperature field were investigated in float glass furnace,under different horizontal width of the melting pools.The simulating results show that,the situation of glass flow in the neck and cooling will not be changed significantly by reducing the horizontal width of the melt pools at the bottom,and thus it does not affect the furnace capacity.But different horizontal width of the molten pools at the bottom will result in temperature field change of melting pools.Axial surface of temperature decreases,while the parapet temperature increases,which will lead to change of horizontal temperature gradient,exacerbate horizontal convection of glass flow,and will help homogenization and clarification of glass flow.
What problem does this paper attempt to address?