Degradation Behaviour of Epoxy in Stator Insulation Based on Thermogravimetry and Infra-red Spectrometry

HAO Yan-peng,XIE Heng-kun
DOI: https://doi.org/10.3321/j.issn:0258-8013.2008.13.003
2008-01-01
Abstract:The degradation behavior of epoxy in stator insulation under operating stresses was investigated by thermogravimetry and infra-red spectrometry.The insulation specimens were cut from a standby and an aged stator bar in a 300 MW/18 kV generator operating for 23 years.It is found that the weight loss measured by thermogravitary on some aged insulation increases,and addition two reaction intervals present in TG or DTG curve of other aged insulation.Based on infra-red spectrum of aged insulation it is found that the absorption peaks due to C=O and —OH increase obviously,those due to —CH3 and —CH2 decrease significantly,and that due to C—C decreases in intensity.The aging mechanism of epoxy in stator insulation under operating stresses for a long term might be the rupture of fundamental chain and the oxidation of branched chain.
What problem does this paper attempt to address?