Study on the determination of the dimension of capillary tubes by equivalent method

Rao Rongshui,Gu Bo,Zhou Ze,Zhao Jun
DOI: https://doi.org/10.3969/j.issn.1009-8402.2006.03.005
2006-01-01
Abstract:Based on analogy and equivalent method, presents an improved equivalent method to transform the capillary tube length and inner diameter. Points out that the friction factor affects the improved equivalent method directly. The variation for different friction factor equation to calculate the capillary tube length by improved equivalent method is within 6% if N/Neq equals to 1.5. The difference of the inner diameter of capillary tubes between equivalent method and experiment for a 18 kW heat pump unit is -7.2% and -6.5%, and the difference of the length of capillary tubes between equivalent method and experiment for a 18 kW heat pump is 2.9 % and 12.7%, by selecting the capillary tube dimension of air conditioner of 8.5 kW and 9.85 kW, respectively.
What problem does this paper attempt to address?