Analysis of wind-induced dynamic response of super large cooling tower

Li Xu,Li Xiaowen
2011-01-01
Abstract:Taking a super large cooling tower as a research object,using MATLAB,the time histories of wind velocity are simulated according the liner Auto-Regressive(AR) method.The wind-induced dynamic response of the tower is calculated with the finite software ANSYS and analysed in the time domain under the wind load of 0.direction.The results show that:the wind vibration factor is small at the middle of the tower and increases gradually both to the top and the bottom of the tower;the wind vibration factor is big at the bottom of the tower due to the small mean displacement caused by the constraint of the X-columns and the ring beam,which makes it meaningless;it shows that it's reasonable to make the wind vibration factor of the whole cooling tower as 1.7.
What problem does this paper attempt to address?