Steel Pipe Node Test of the 500 Kv Hanjiang River Crossing Tower Steel

Yong He
2010-01-01
Abstract:The Q420 high-strength steel pipe has been tested through pilot projects by the SGCC for its applicability and safety when applied to transmission towers.The large-span Hanjiang river-crossing towers for 500 kV transmission lines used the Q420 high-strength steel pipe as main members and three types of K-shaped nodes were tested with six specimens.An analysis was performed on the nodes under load in terms of the stress distribution on cross-section,lateral displacement of the main pipe and the ultimate stress state,which provided reliable basis for tower design and safe operation of the transmission lines.The test result indicates that the reinforcement board and the angle between the main pipe and branch pipe have significant impacts on the distribution of nodes.