The clinical Research on Different Retrograde Perfusion Pressure through Coronary Sinus for Myocardial Protection

YAO Hao,WANG Qiang,CHEN Yang,SUN Xu
DOI: https://doi.org/10.3969/j.issn.1672-1403.2013.01.005
2012-01-01
Abstract:Objective To compare the myocardial protective effects of different perfusion pressures of retrograde coronary sinus cardioplegia.Methods 60 rheumatic heart disease cases performed bivalvular replacement were divided into two groups randomly,with 30 cases for each.Every patient was performed the technique of primary antegrade coronary sinus cardioplegia combined with secondary retrograde coronary sinus cardioplegia.The perfusion pressure was 30 mmHg in group A,and 40 mmHg in group B.The different effects were compared between two groups.Results Compare to group A,the patients had fewer dopamine usage,shorter mechanical ventilation time and ICU stagnation time after operation in group B(P<0.05),and the level of CK-MB,LDH and cTn-I were obviously lower after operation in group B(P<0.05).Only one patient appeared the low cardiac output syndrome in group A.Conclusion The retrograde perfusion pressure of 40 mmHg can induce better myocardial protective effect than 30 mmHg in the proper extent.