RP -HPLC Determination of Content and Related Substances of Topotecan Hydrochloride and Its Preparation

李语如,顾萍,韦艳丽,朱俊杰
2005-01-01
Abstract:Objective:To establish RP - HPLC method for determination of the content of topotecan hydrochloride and its related substances in raw material and its preparations. Method:A C18 column was used with the mobile phase of 0.5% phosphoric acid and 0.5% n - butylamine (v/v)-methanol(60:40) at a flow rate of 1.0 mL· min " and the detection wavelength of 267 nm. Results: The topotecan hydrochloride and related substances can be baseline separated. The calibration curve was linear in the range of 10-100μg·mL-1 with r=0.9999. The detection limit was 0.02 ng. The precision(RSD) was 0.41% (n=9) and the average recovery from the preparation was 99.3%.Conclusion:This method is rapid, simple and can be used for determination of the content of topotecan hydrochloride and its related substances in raw material and its preparations.