Experimental Study on the Performance of Loop-Seal in a Horizontal Circulating Fluidized Bed Boiler

Li Qinghai,Gan Chao,Feng Heng,Zhang Yanguo
DOI: https://doi.org/10.11715/rskxjs201303001
2013-01-01
Abstract:In order to study the working performance of the loop-seal with a low standpipe,an experimental facility,taking the 12 t/h steam boiler as the prototype,was designed and installed on a scale of 1∶1.The effects of supply aeration,recycle aeration and bed materials on the working performance of loop-seal were studied.The experimental results show that the bed material recycle rate increases with the increase of the supply and recycle aeration.The bed material recycle rates reach saturation when the recycle aeration fluidizing number approaches 1.0 for river sand and 1.5 for rice husk ash,respectively.The more the supply aeration,the higher the saturated bed material recycle rate,which is similar to the working performance of a triode.The bed material recycle rate can be adjusted alone by the supply aeration,while the saturation of loop-seal is attributed to the increase of supply aeration.The experimental loop-seal is similar to the commercial one in the size of loop-seal and height of standpipe.Thus,the experimental results are expected to be useful for the engineering design of commercial horizontal circulating fluidized bed boilers.
What problem does this paper attempt to address?