Design and test requirements of main loop shut-off valves in the helium test loop

LIU Ji,YANG Ming-de,DANG Jie,CHEN Zhen,BO Han-liang,ZHANG Zuo-yi
2012-01-01
Abstract:The Helium Test Loop(HTL)is under construction for the engineering verification testing and thermodynamic engineering performance testing of the key equipment of High Temperature Gas Cooled Reactor(HTR).Main loop shot-off valves in HTL,which were boundary to other systems,were of great importance to the steady operation of HTL.At the same time,valves offered the greatest number of potential leak point.Favorable sealing property of valves would make significant contribution to reducing the leakage of the test loop.In this paper,the operating requirements of the HTL main loop are introduced;the design and selection,flow capacity,sealing property,and drive mode of main loop shut-off valves are presented.The testing requirements and implementation process are discussed as well.
What problem does this paper attempt to address?