Maintenance for Heat Recovery Steam Generator of 800 MW-class Gas-steam Combined Cycle Unit

Wu Feng,Zhang Yu-zhuan,Zhao Xi,Si Pai-you,Mao Yong-qing,Zhang Qing-feng,Wang Hong-tao,Zhou Yi
DOI: https://doi.org/10.3969/j.issn.1003-9171.2013.07.007
2013-01-01
Abstract:In this paper,the stopped boiler corrosion principles and protection methods of Heat Recovery Steam Generator(HRSG) of combined gas-stream cycle unit are introduced.The HSRG No.1 in Beijing Jingqiao thermal plant is taken as an example to introduce the maintenance principle and the concrete operating procedures of ammonia-hydrazine passivation drying method and rushed nitrogen wet maintenance method used during commissioning of the boiler.And the attention points of different maintenance methods are proposed.