Analysis on the Steam Temperature Deviation of the Vertical Water Wall and the Adjustment Plan of the Throttle Ring for an Ultra-supercritical Boiler
YANG Haoyu,ZHANG Xirong,LI Weiteng,YANG Dong,WANG Yongjie,SONG Baojun,XIA Liangwei
DOI: https://doi.org/10.19805/j.cnki.jcspe.2023.05.003
2023-01-01
Abstract:Experimental research and hydrodynamic calculation were carried out to solve the problems of deviation in steam temperature, large temperature fluctuation and the transverse cracks in the lower furnace water wall of a 660 MW ultra-supercritical boiler. According to the boiler design scheme, a hydrodynamic calculation mathematical model for the boiler flow network system was established, and the temperature test points were arranged on the water wall. Based on the actual furnace measurement data of the steam temperature, the heat load and thermal deviation distribution in the unit 1 furnace at 270 MW load was calculated. Then the arrangement of the throttle ring was adjusted, and the adjusted hydrodynamic and flow instability was calculated. Results show that the outlet steam temperature is more uniform and the adjustment can prevent steam temperature fluctuation without pulsation. At the same time, the steam temperature distribution of the lower furnace water wall at medium and high loads is more uniform after the throttle ring adjustment, and the temperature deviation is significantly improved.