Effects of pacing on hemodynamics in right ventricular outflow tract

LIU Qing-jun,QIAN Jian-feng,LIU Feng,PAN Wen,MAO Jia-liang
2008-01-01
Abstract:AIM To compare the effects of pacing on hemodynamics in right ventricular septum and in right ventricular apex. METHODS Thirty patients performed with DDD or VVI pacing were grouped randomly into two groups,15 patients in one group received RVS pacing,while 15 patients in the other group received RVA pacing. The QRS waves of the ECG of the preoperation and the postoperation were recorded and analyzed. The hemodynamic parameters of LVEF,SV,FS and CI were compared between preoperation,3 months and 6 months after operation by echocardiography. RESULTS The QRS duration in RVA group was longer than that in RVS group significantly [(158±15) vs (132±15)ms,P<0.01]. Compared with RVA pacing,RVS pacing better improved LVEF,SV,FS and CI [(58±4) vs (51±3)%,(77±15) vs (71±16)ml,(0.37±0.10) vs (0.31±0.09),(2.5±0.4) vs (2.1±0.4)L/(min·m2),P<0.05] three months after implantment of pacemakers. The LVEF,SV,FS and CI of RVA group 3 months after operation decreased significantly [(59±3)% vs (51±3)%,(79±15)ml vs (71±16)ml,(0.36±0.11) vs (0.31±0.09),(2.5±0.4) L/(min·m2) vs (2.1±0.4)L/(min·m2),P<0.05)]. CONCLUSION Compared with RVA pacing,RVS pacing presents a more physiological depolarization pattern and better hemodynamics.
What problem does this paper attempt to address?