A Novel 2-D Random Void Model and Its Application in Ultrasonically Determined Void Content for Composite Materials

Li Lin,Jun Chen,Xiang Zhang,Ximeng Li
DOI: https://doi.org/10.1016/j.ndteint.2010.12.003
IF: 4.683
2011-01-01
NDT & E International
Abstract:A two-dimensional (2-D) Random Void Model (RVM) is innovatively developed to describe random voids and to quantitatively correlate ultrasonic attenuation coefficient with void content of composite materials. The spatial autocorrelation function and statistical parameters are used to describe the large-scale heterogeneity from the composite matrix and the small-scale heterogeneities of elastic fluctuations from random voids. The RVMs of Carbon Fiber Reinforced Polymer (CFRP) composite specimens over a void content range of 0.03–4.62% are presented. Outstanding improvements of geometric simulations of voids morphology and quantitative correlation of porosity and ultrasonic attenuation coefficient at 5MHz are observed. It is concluded that this method is suitable to identify random voids and to predict void content of composite materials nondestructively.
What problem does this paper attempt to address?