Control of Leakage Rate in Spiral Groove Mechanical Seal

Zhou Jianfeng,Gu Boqin,Chen Ye
DOI: https://doi.org/10.3969/j.issn.0254-0150.2007.05.037
2007-01-01
Abstract:The end faces of sealing rings of spiral groove mechanical seal are lubricated by fluid film and the thermal deformation of sealing rings takes place under the load of frictional heat of fluid film.The coupling analysis of fluid flow,heat transfer and thermal deformation was carried out in consideration of viscosity change with temperature,the gap form and leakage rate corresponding to certain closing force were determined.The result shows that the leakage rate can be controlled by adjusting the closing force.The increase of closing force results in the decrease of thickness of fluid film,the increase of frictional torque and decrease of leakage rate.
What problem does this paper attempt to address?