Initial Application of BMI Adapted and Iterative Reconstruction in Prospective Cardiac Computed Tomography Angiography Examination

苟文静,刘士远,萧毅,于红,李琼,陈如谭,吴雪高
DOI: https://doi.org/10.13437/j.cnki.jcr.2013.10.012
2013-01-01
Abstract:Objective To evaluate the value of BMI-adapted and iterative reconstruction technique in prospective cardiac computed tomography angiography examination. Methods Ninety one consecutive patients who underwent cardiac CTA scans were divided into 3 groups. In group A,42 cases underwent cardiac CTA using conventional dose( 120 kV,200 mAs)and filter Back Projection technique. 49 cases underwent CTA using low dose,FBP was applied in group B and iDose was applied in group C. Image quality,noise,volume CT dose index( CTDIvo1) and effective dose( ED) were measured. Results SNR and CNR were similar in group A and C,while SNR and CNR in group B were lower than group A and C. The ED in low dose group was 69% lower than in conventional group( 0. 95 ± 0. 40 versus 3. 07 ± 0. 50 mSv,respectively; P <0. 01). Conclusion Combining BMI adapted prospective cardiac computed tomography angiography and iterative reconstruction technique can reduce radiation dose remarkably without image quality reducing.
What problem does this paper attempt to address?