Application of Adaptive Statistical Iterative Reconstruction (ASIR) in Brain CT Scan

曹新鸣,郭小超,王霄英,刘建新,赵凯
DOI: https://doi.org/10.3969/j.issn.1000-0313.2013.05.002
2013-01-01
Abstract:Objective:To study the application of a new CT reconstruction algorithm,adaptive statistical iterative reconstruction(ASIR) plus automatic tube current modulation techique,to reduce radiation dose in brain CT scan.Methods:One hundred patients(from Mar 2012 to Jun 2012) were included in this study,randomly divided into two groups.Group A:50 patients underwent conventional brain CT scan(120kVp,350mA) with filtered back projection reconstruction.Group B:50 patients underwent brain CT scan(120kVp,modulate tube current) with 30% ASIR techique.The radiation doses of the two groups(CTDI,DLP,SSDE) were compared.The image quality was analyzed by an experienced radiologist.CT value of normal white matter,gray matter and cerebrospinal fluid were measured at basal nuclei level.For each patient,the ROIs(10~20mm2) were settled in the same location.Results:The radiation doses(CTDI、DLP and SSDE) of group A were much lower than those of group B(P0.01).All the images could satisfy diagnostic acceptability.There was no significant difference in CT value of normal white matter,gray matter and cerebrospinal fluid of the two groups(P0.05).Conclusion:In brain CT scan,ASIR combined with automatic tube current modulation technique,compared with conventional FBP,can provide same image quality and reduce the radiation dose without having effect on CT value.
What problem does this paper attempt to address?