Influence of Different Construction Measures on Temperature Stress in Over-long Concrete Frame Workshop

Hong-lei WU,Min LUO,Jin-long PAN
DOI: https://doi.org/10.3969/j.issn.1005-6270.2009.04.011
2009-01-01
Abstract:For over-long reinforced concrete frame structure,temperature loading often leads to crack formation of the beams and plates.With the software of SAP2000,this article analyzed temperature stress of an over-long frame structure under the dropping temperature condition,and obtained the maximum principal stress distribution.Shear wall,expansion reinforcing strip,expansion joint were employed to decrease the temperature effect.The results demonstrate that the latter two measures can apparently minimize the first principal stress of concrete slabs and the lateral displacement of columns.Though displacement of columns decreases when shear walls are employed in the structure,concrete cracks occur due to significant increase of the principal tensile stress.Finally,based on the calculation results,specific control measures are put forward to control the occurrence cracks in over-long reinforced concrete during the stage of design and construction.
What problem does this paper attempt to address?