Update of beam coupling impedance evaluation by the stretched-wire method
T. Toyama,A. Kobayashi,T. Nakamura,M. Yoshii,C. Ohmori,K. Hasegawa,Y. Sugiyama,T. Shibata,K. Ishii,Y. Shobuda,F. Tamura,K. Hanamura,T. Kawachi
DOI: https://doi.org/10.48550/arXiv.2208.09217
2022-08-23
Abstract:In many cases beam coupling impedances or wake fields are calculated with computer simulator such as CST Studio Suite, GdfidL Electromagnetic Field Simulator and so on. But evaluation with the stretched-wire method is still very useful by its flexibility to the change of the device-under-test configuration, speed to get results and, more than anything, its accessibility on the real devices. One of the drawbacks in the practical procedure, difficulty of Thru-Reflect-Line calibration, is overcome using the calibration method recently introduced in high frequency vector network analyzers, "2-X THRU de-embedding". Here the procedure is explained in detail. The method has been successfully applied to RF cavity and FX kicker measurement in the J-PARC MR.
Accelerator Physics