Measurement Methods and Impact Factors for Light Output Fluctuation of Light Sources

Zhuang Xiaobo,Zhu Shaolong,Zhang Shanduan
DOI: https://doi.org/10.3969/j.issn.1004-440X.2009.01.003
2009-01-01
Abstract:Fluctuation depth(FD),flicker index and modulation depth were defined to characterize the light variations of light sources.Four detectors were compared,including linear illuminance sensor(LIS),photodiode,conventional illuminance detector and photomultiplier.The results show LIS is the best detector for flicker measurement and photodiode may also be used in simple measurement.The FD and flicker index of generally-used light sources were measured with LIS.The FD of tungsten filament lamps is 6%~31% and decreases with increasing power.For fluorescent lamps driven by magnetic ballast,the FD is 42%~48%;and <10% by high quality electronic ballast.The FD of metal halide lamps driven by electronic ballast with rectangular waveform is <3%,which is lower than 1/20 of that driven by magnetic ballast.The relationship between the power waveform and light flicker is analyzed.For electronic ballast of fluorescent lamps,in order to reduce the FD the 50 Hz modulation has to be smooth,and for that of high intensity discharge lamps the zero passage at current reverse needs to be as shot as possible.