Combined curvilinear regression method for calculating convective heat transfer coefficient in spiral flat tubes

Yang Sheng,Zhang Li,Xu Hong,Zeng Xiantai
DOI: https://doi.org/10.3969/j.issn.1001-7100.2011.07.016
2011-01-01
Abstract:In consideration of the difficulty in measuring the wall temperature of spiral flat tubes accurately,a linear-nonlinear combined curvilinear regression method was introduced to calculate the heat transfer coefficient in tubes.The inside tube convective heat transfer experiment of round tube and spiral flat tube was conducted and the method was utilized to calculate the tube side heat transfer coefficient.The calculated heat transfer coefficient of a round tube had a 6% deviation with the value by classical computing formula.The calculated heat transfer coefficient of spiral flat tubes was slightly larger than the valve obtained by measuring the wall temperature,and the reason of the difference was analyzed.The combined curve fitting method can eliminate the error caused by wall temperature measurement and further improve the accuracy of test results.