Calculation of the Temperature Field Distribution in an Electrically Heated Inclined Tube

高峰,尹飞,陈听宽,罗毓珊
DOI: https://doi.org/10.3969/j.issn.1001-2060.2005.05.007
2005-01-01
Abstract:Taking into account the impact of natural convection on the fluid heat transfer in an inclined riser tube the outer wall temperature and heat load are assumed as boundary conditions.Meanwhile,with the internal heat source being treated as a parallel-connected network resistance heat-release a two-dimensional mathematical model was set up for assessing the temperature field distribution in an electrically heated inclined tube.A controlled-volume differential method based on spatial node advance was used to solve the inverse problem of a two-dimensional temperature field heat conduction in an electrically heated inclined tube,which is determined by the coupling of fluid heat exchange and tube wall heat conduction.A computation program was prepared and the calculation of tube-wall temperature field conducted for the tube type of the spiral tube-coil water-wall of the first supercritical-parameter boiler in China.Under the operating condition of subcritical and supercritical pressures the calculation results can all truly reflect the wall-temperature distribution law of the inclined tube with a fairly good computation convergence being attained.
What problem does this paper attempt to address?