Active breath coordinator enhances the precision of image guided radiotherapy for lung cancer

ZHONG Ren-ming,XU Feng,HE Ying-bo,JIANG Qing-feng,LI Xiao-yu,BAI Sen
DOI: https://doi.org/10.3760/j.issn:1004-4221.2007.06.006
2007-01-01
Abstract:Objective To prolong breath holding time by using active breath coordinator (ABC) and to improve the precision of image guide radiotherapy (IGRT) for lung cancer. Methods Thirty -one patients with lung cancer were trained for breath holding with inhalation of 61% oxygen for approximately 30 minutes every day, at least 5 days totally. Results The maximal breath holding time over 40 seconds was observed in 24 patients (77%) after training. The average maximal breath holding time was 65.5 seconds, which was 33.9 seconds longer than that before training. The average motions of the diaphragm in GT direction using ABC and free breathing were 1.7 mm and 16.0 mm. The average errors in AB,GT and AP directions were 3.3 mm,4.8 mm and 3.1 mm for the first setup. After adjusting the isocenter, the errors were reduced to 1.0 mm ,1.2 mm and 1.1 mm. Conclusions The breath holding time can be markedly extended by breath training and inputting oxygen. When combined with active breath coordinator, the precision of image guide radiotherapy for lung cancer is less than 2 mm, which makes it possible to increase fraction dose and total dose while decrease lung damages.