Experimental Studies Long-term Behavior of FRP Retrofitted RC Columns with Earthquake Loading Damage

单波,肖岩
DOI: https://doi.org/10.3969/j.issn.1000-5900.2008.04.014
2008-01-01
Abstract:Despite the significant importance,long-term seismic behavior of reinforced concrete(RC) columns retrofitted with fiber-reinforced plastic(FRP) has received little attention.In this paper,the residual performance of FRP retrofitted columns damaged after simulated seismic loading is studied.Eight model columns with a shear aspect ratio of 5.0 were tested first under cyclic lateral force and a constant load equal to 20% of the column gross axial load capacity.The main parameters considered were the type of FRP jacket and peak drift ratio where the lateral loading was interrupted.Glass-fiber-reinforced plastic(GFRP) and Carbon-fiber-reinforced plastic(CFRP) were both used for retrofitting.Five of the model columns were subjected to long-term axial loading after subjected to limited damage by lateral cyclic loading.The deformation of retrofitted columns under long-term axial loading depended on the previous damage intensity and the modulus of FRP.Under the testing condition of this study,the long-term axial deformation of retrofitted column tends to be stable,despite subjected simulated earthquake damage.
What problem does this paper attempt to address?