Research on CFRP confined circular concrete-filled steel tubular columns subjected to cyclic lateral forces

Peng QIN,Yan XIAO,Yun ZHOU,Guowei ZHANG
DOI: https://doi.org/10.13197/j.eeev.2013.05.190.qinp.024
2013-01-01
Abstract:Reversed cyclic loading under constant axial load experiment was conducted on 2 conventional concrete filled steel tubular (CFT) columns and 4 carbon-fiber-reinforced polymer (CFRP) confined concrete filled steel tubular (CFT) columns. Failure mode, hysteretic behavior and energy dissipation were investigated. The experimental results show the horizontal restraining by carbon-fiber changes the failure mode of the CFT. Based on the cyclic energy consumption of the specimens, a cumulative damage model based on fatigue energy consumption was established to simulate the damage extent of the column. The relationship between energy dissipation and damage index was analyzed, and we found that the different loading sequence has influence on the specimen damage. The damage index was increased with the cyclic amplitude, however the total energy consumption and the final damage index achieve the same level when the parameters are the same. The energy consumption of the specimens has good correlation with the damage index. This indicates the proposed model could be used for accumulative damage evaluation.
What problem does this paper attempt to address?