Low-cycle fatigue test of CFT and CCFT columns

Guo-Wei Zhang,Yan Xiao,Sashi Kunnath
2006-01-01
Abstract:Under seismic actions, the damage of critical regions of a CFT column can be regarded as combined results of cumulative damage caused by cyclic loading with different displacement levels after yielding. To develop a more rational damage criterion for circular CFT columns subjected to a series of earthquake excitations, an experimental study is undertaken to investigate the cumulative damage and relationship between low cycle fatigue life and displacement amplitude. The collapse characteristics of the tested specimens containing of standard cyclic loads and constant amplitude tests were presented in details to provide useful information for understanding their inelastic behavior in this paper. The low-cycle fatigue characteristics of typical flexural CFT columns are discussed. For comparison, a confined CFT column (CCFT) confined with steel collar was also tested, which showed improved fatigue life.