Fuel Irradiation of the First Batches Produced for the Chinese HTR-10

CH Tang,XM Fu,JG Zhu,TX Liang,KN Koshcheyev,AV Kozlov,OG Karlov,YG Degaltsev,VI Vasiliev
DOI: https://doi.org/10.1016/j.nucengdes.2005.11.001
IF: 1.7
2006-01-01
Nuclear Engineering and Design
Abstract:An irradiation test of four spherical fuel elements (SFE) had been performed in the Russian reactor IVV-2M. The elements were sampled randomly from the first and second product batches which were manufactured for the 10MW high-temperature gas-cooled test reactor (HTR-10). The maximum burnup of the irradiated fuel elements reached 107,000MWd/tU and the maximum fast neutron fluence was 1.31×1025m−2. The release-to-birth rate ratio (R/B) did not increase significantly during irradiation. However, an in-pile heating-up test of element SFE 7 in Capsule 5 led to a failure of approximately 6% of the coated particles. After the test it was estimated that the fuel temperature had very likely been much higher than the intended 1600°C.
What problem does this paper attempt to address?