Abstract:The present study demonstrates that the relation of the electric pressure and fractional collection efficiency in an electrostatic precipitator(ESP).The results showed that they have a positive correlation(R2=0.9753).The test showed that the maximum fractional collection efficiency was above 99.4 %.The influences of electric pressure(corona charging field) was obtained.The process of ESP involves the ionization of contaminated air flowing between electrodes,the charging migration and collection of the particales on oppositely charged plates and the removal of the particles from the plates.Under the other conditions constant,The drift velocities could be remarkably improved by increasing electric pressure values and reached the optimum condition.